¼³°è Ư¡
- 4°³ÀÇ ¿¡¾î·ÎÅØ ÄÁÆ®·Ñ·¯¿¡ ´ëÇØ AC ¶Ç´Â DC ¹ö½º °ø±Þ Àü¾ÐÀ» Á¦°ø
- 300w ÃÖ´ë Àü·Â Ãâ·Â(TM3); 500w ÃÖ´ë Àü·Â Ãâ·Â(TM5)
- 4°³ Ãß°¡ Á¦Ç°¿¡ Àü¿øÀ» ³Ö±â À§ÇÑ º¸Á¶ °ø±Þ Ãâ·Â
TM3 Æ®·£½ºÆ÷¸Ó ¸ðµâ
TM3 Æ®·£½ºÆ÷¸Ó ¸ðµâÀº 4°³ÀÇ ¿¡¾î·ÎÅØ ÄÁÆ®·Ñ·¯¿¡ ´ëÇØ °Ý¸®µÈ AC ¶Ç´Â DC ¹ö½º °ø±Þ Àü¾ÐÀ» Á¦°øÇÏ°í ¹èÆ÷ÇÕ´Ï´Ù. °øÀå¿¡¼ 300WÀÇ ÃÖ´ë Æ®·£½ºÆ÷¸Ó Ãâ·Â Àü·Â ¼º´ÉÀ¸·Î 28 VAC, 56 VAC, 115 VAC, 40 VDC, 80 VDC, ¶Ç´Â 160 VDC ¸¦ Á¦°øÇϱâ À§ÇØ ±¸¼ºµÇ¾ú½À´Ï´Ù.
°Ô´Ù°¡, TM3 ´Â 4°³ ¿¡¾î·ÎÅØ Á¦Ç°¿¡ º¸Á¶ Àü·Â Ãâ·Â¿¡ Àü¿øÀ» ³Ö±â À§ÇÑ º¸Á¶ °ø±Þ Ãâ·ÂÀ» Á¦°øÇÕ´Ï´Ù. TM3 ¶ÇÇÑ 0.9amp ±îÁöÀÇ Àü·ù ¿ë·®Àº 24VDC Ãâ·ÂÀ» »ç¿ëÀÚ¿¡°Ô Á¦°øÇÏ´Â 24 VDC Àü¿ø °ø±ÞÀ» Æ÷ÇÔÇÕ´Ï´Ù. TM3ÀÇ ´Ù¸¥ Ư¡Àº µ¹ÀÔ Àü·ù¸¦ Á¦ÇÑÇÏ´Â ¼ÒÇÁÆ®-½ºÅ¸Æ® ȸ·Î¿Í 100 VAC, 115 VAC, 200 VAC, ¶Ç´Â 230 VACÀÇ AC ÀÔ·Â Àü¾ÐÀ» ±¸¼ºÇÒ ¼ö ÀÖ´Â Àü¾Ð ¼±ÅÃÀ» Æ÷ÇÔÇÕ´Ï´Ù.
TM5 Æ®·£½ºÆ÷¸Ó ¸ðµâ
TM5 Æ®·£½ºÆ÷¸Ó ¸ðµâÀº 4°³ÀÇ ¿¡¾î·ÎÅØ ÄÁÆ®·Ñ·¯¿¡ ´ëÇØ °Ý¸®µÈ AC ¹ö½º °ø±Þ Àü¾ÐÀ» Á¦°øÇÏ°í ¹èÆ÷Çϱâ À§ÇØ »ç¿ëµË´Ï´Ù. °øÀå¿¡¼ 500W ÀÇ ÃÑ Ãâ·Â Àü·Â ¼º´ÉÀ¸·Î 28 VAC, 56 VAC, 115 VAC, ¶Ç´Â °Ô Àü¾ÐÀÇ Á¶ÇÕÀ» Á¦°øÇϱâ À§ÇØ ±¸¼ºµÇ¾ú½À´Ï´Ù. °Ô´Ù°¡, TM5 ´Â ´Ù¸¥ ¿¡¾î·ÎÅØ Á¦Ç°¿¡ º¸Á¶ Àü·Â Ãâ·Â¿¡ Àü¿øÀ» ³Ö±â À§ÇØ ÀÀ¿ëµÈ AC ¶óÀÎ Àü¾ÐÀ» °¢ º¸Á¶ °ø±Þ Ãâ·Â¿¡ ºÐ¹èÇÕ´Ï´Ù. TM5´Â ¶ÇÇÑ 1amp ±îÁö Àü·ù ¿ë·®ÀÎ 24 VDC Ãâ·ÂÀ¸·Î »ç¿ëÀÚ¿¡°Ô Á¦°øÇÏ´Â 24 VDC Àü¿ø °ø±Þ ¿É¼ÇÀ¸·Î ÆÇ¸ÅµÉ ¼ö ÀÖ½À´Ï´Ù. |
Model |
TM3 |
TM5 |
Type |
Isolation |
AC Input Configurations |
100 VAC, 115 VAC, 200 VAC, 230 VAC |
Peak AC Input Inrush Current |
32 Apk |
200 Apk |
Operating Frequency |
50/60 Hz |
Maximum Continuous Transformer Output Power |
300 watts max @ 20¡ÆC |
500 watts max @ 20¡ÆC |
Peak Transformer Output Power |
400 watts max @ 20¡ÆC |
800 watts max @ 20¡ÆC |
Short Circuit/Over Current Protection |
AC input 10 A breaker/switch (supplementary protection only); 100 VAC/115 VAC configurations contain 4 A slow-blow fuse connected to transformer primary winding; 200 VAC/230 VAC configurations contain 3 A slow-blow fuse connected to transformer primary winding |
AC input 10 A breaker/switch (supplementary protection only); 100 VAC/115 VAC configurations contain 8 A slow-blow fuse connected to transformer primary winding; 200 VAC/230 VAC configurations contain 4 A slow-blow fuse connected to transformer primary winding |
Thermal Protection |
Integral transformer thermal switch is normally closed. Thermal switch opens when internal temperature of transformer reaches 110¡ÆC. |
Integral transformer thermal switch is normally closed. Thermal switch opens when internal temperature of transformer reaches 110¡ÆC. |
Secondary Winding Configuration |
28 VAC (40 VDC bus); 56 VAC (80 VDC bus); ¡¾10 VDC, ¡¾20 VDC, ¡¾30 VDC, ¡¾40 VDC |
28 VAC (40 VDC bus); 56 VAC (80 VDC bus); 112 VAC (160 VDC bus) |
+24 VDC Output |
0.9 A max |
0.9 A max |
|
TM Series Transformer Modules
|
Ordering Example
TM3 |
A |
80VDC |
80VDC |
NO
SPLIT |
PS24-1 |
Ordering Options
Base |
Line Voltage |
Bus Voltage 1 |
Bus Voltage 2 |
Axis Split |
Power Supply |
TM3 |
A B C D |
80 VDC 56 VAC 40 VDC 28
VAC |
80 VDC 56 VAC 40 VDC 28
VAC |
2-2 NO SPLIT |
PS24-1 |
TM5 |
A B C D |
115 VAC 56 VAC 28 VAC 56 VAC
CT |
115 VAC 56 VAC 28 VAC 56 VAC
CT |
1-3 2-2 3-1 NO SPLIT |
PS24-1 |
TM3/TM5 Transformers
Option |
Description |
TM5 |
0.5 kVA isolation transformer in enclosure with power switch, 4
AC voltage motor power outputs and aux power connections |
TM3 |
0.3 kVA isolation transformer in enclosure with power switch, 4
AC or DC voltage motor power outputs and aux power
connections |
Line Voltage
Option |
Description |
A |
115 VAC |
B |
230 VAC |
C |
100 VAC |
D |
200/208 VAC |
Bus Voltage (Vbus1)
Option |
Description |
115VAC |
115 VAC (for 160 VDC bus); TM5 only |
56VAC |
56 VAC (for 80 VDC bus) |
28VAC |
28 VAC (for 40 VDC bus) |
56VAC CT |
56 VAC center tap for Ensemble CL drives (for 40 VDC
bus) |
80VDC |
80 VDC (for input to MP drives); TM3 only |
40VDC |
40 VDC (for input to MP drives); TM3
only |
Bus Voltage (Vbus2)
Option |
Description |
115VAC |
115 VAC (for 160 VDC bus) |
56VAC |
56 VAC (for 80 VDC bus) |
28VAC |
28 VAC (for 40 VDC bus) |
56VAC CT |
56 VAC center tap for Ensemble CL drives (for 40 VDC
bus) |
80VDC |
80 VDC (for input to MP drives); TM3 only |
40VDC |
40 VDC (for input to MP drives); TM3
only |
Axis Split (Vbus1 Vbus2)
Option |
Description |
1-3 |
Axis 1 Vbus 1; Axis 2,3,4 Vbus 2 |
2-2 |
Axis 1,2 Vbus 1; Axis 3,4 Vbus 2 |
3-1 |
Axis 1,2,3 Vbus 1; Axis 4 Vbus 2 |
NO SPLIT |
Vbus 1 and Vbus 2 ties together and wired to all
axes |
Optional Power Supply
Option |
Description |
PS24-1 |
24 VDC, 1 amp power supply for brake
control |
Optional Brake Cable (Only selected when /PS241 is
selected)
Option |
Description |
C24-06 |
6DM (2 ft) 2 conductor brake cable with flying
leads |
C24-09 |
9DM (3 ft) 2 conductor brake cable with flying
leads |
C24-12 |
12DM (4 ft) 2 conductor brake cable with flying
leads |
C24-15 |
15DM (5 ft) 2 conductor brake cable with flying
leads |
C24-18 |
18DM (6 ft) 2 conductor brake cable with flying
leads |
/CABLE1/CABLE2/CABLE3/CABLE4
Option |
Description |
C1 |
Cable AXIS 1 |
C2 |
Cable AXIS 2 |
C3 |
Cable AXIS 3 |
C4 |
Cable AXIS 4 |
Cable Type
Option |
Description |
AB |
Bus and Aux Power |
B |
Bus only |
Standard Cable Lengths
Option |
Description |
06 |
6DM (2 ft) |
09 |
9DM (3 ft) |
12 |
12DM (4 ft) |
15 |
15DM (5 ft) |
18 |
18DM (6 ft) |
LINECORD
Option |
Description |
ENGLAND |
U.K. compatible line cord |
GERMANY |
German compatible line cord |
ISRAEL |
Israel compatible line cord |
INDIA |
India compatible line cord |
AUSTRALIA |
Australia compatible line cord |
US-115VAC |
U.S. 115 VAC line cord |
US-230VAC |
U.S. 230 VAC line cord |
NO-LINECORD |
No line cord | |